Weights |
|
Boom / Stick / Bucket |
Breakout Force | 58450 lb
| Bucket Capacities | 4.6-12.0 m (6.0-15.75 yd)
|
---|
|
Engine & Fuel System |
Engine Model | Cat C13 ACERT
| Fuel Tank | 112.5 gal
| Maximum Net Torque - 1,000 Rpm | 1505 lb ft
| Maximum Net Torque - 1,100 Rpm | 1518 lb ft
| Net Power - Iso 9249 | 398 hp
| Emissions | Cat engine with ACERT Technology ? meets Tier 2/Stage II, Tier 3/Stage IIIA equivalent emission standards.
| Cooling System | 14 gal
| Displacement | 763 cu in
|
---|
|
Drive System |
Brakes | Brakes meet ISO 3450:2011 standards
|
---|
|
Hydraulic System |
Hydraulic Cycle Time - Total | 10.1 s
| Hydraulic Tank | 48 gal
| Implement Pump Type | Variable Displacement Piston
|
---|
|
Dimensions, Wheels & Tires |
Maximum Width Over Tires | 11.5 ft in
| Ground Clearance | 1.33 ft in
| Overall Length - Without Bucket | 28.17 ft in
| Wheel Base | 12.5 ft in
| Front | Fixed
| Rear | Oscillating ?13 degrees
| Height - Top Of Rops | 12.5 ft in
| Rops/Fops | ROPS/FOPS meet ISO 3471:2008 and ISO 3449:2005 Level II standards
|
---|
|
Transmission |
Transmission | 20.3 gal
| Forward - 1 | 3.9 mph
| Forward - 2 | 7.4 mph
| Forward - 3 | 13.1 mph
| Forward - 4 | 23.3 mph
| Reverse - 1 | 4.3 mph
| Reverse - 2 | 8.5 mph
| Reverse - 3 | 15 mph
| Reverse - 4 | 24.5 mph
|
---|
|
Technical Specs |
Height - Top Of Exhaust Pipe | 12.25 ft in
| Height - Top Of Hood | 10.17 ft in
| Hinge Pin Height At Carry | 2.67 ft in
| Rack Back - Carry Height | 48 degrees
| Rack Back - Maximum Lift | 57 degrees
| Rack Back At Ground | 42 degrees
| Tread Width | 8.33 ft in
| Crankcase | 9.8 gal
| Def Tank* | 5.5 gal
| Note | *Distance of 15 m (49.2 ft), moving forward in second gear ratio.
| Bucket Range | 4.6-12.0 m (6.0-15.75 yd)
| Bore | 5.2 in
| Stroke | 6.2 in
| Note (1) | The sound values indicated are for specific operating conditions only. Machine and operator sound levels will vary at different engine and/or cooling fan speeds. Hearing protection may be needed when
| Note (2) | *For a standard machine configuration, measured according to the procedures specified with the cooling fan speed set at maximum value.
| Note (3) | **For a standard machine configuration, measured according to the procedures specified. The measurement was conducted under the following conditions: distance of 15 m (49.2 ft), moving forward in sec
|
---|
|