Weights |
|
Engine & Fuel System |
Engine Crankcase | 5.3 gal
| Engine Model | Cat? C7.1 ACERT?
| Diesel Exhaust Fluid Tank | 4.2 gal
| Fuel Tank | 132.1 gal
| Peak Torque - 1,400 Rpm | 749 lb ft
| Torque Rise | 26%
| Net Power | 248 hp
| Emissions | Brazil MAR-1 and China Nonroad Stage III, equivalent to U.S. EPA Tier 3/EU Stage IIIA
| Displacement | 427.8 cu in
|
---|
|
Drive System |
Brakes | Single Disc Wet (enclosed) 4 WHL
| Relief Valve Setting - Steering | 4003 psi
| Steering Cycle Times - Low Idle | 8.2 s
| Steering System - Circuit | Pilot, load sensing
| Steering System - Pump | Variable displacement piston
|
---|
|
Hydraulic System |
Hydraulic Tank Only | 19.8 gal
| Maximum Flow At 2,200 Rpm | 38.8 gal/min
| Pilot Relief Valve Setting | 3046 psi
|
---|
|
Dimensions, Wheels & Tires |
Length To Front Tire | 20.9 ft in
| Ground Clearance | 1.4 ft in
| Ground Clearance - Bumper | 2.3 ft in
| Wheel Base | 11 ft in
| Front | Planetary-Fixed
| Rear | Planetary Oscillating
|
---|
|
Transmission |
Transmission | 13.2 gal
| Transmission Type | Cat Planetary Power Shift
| Peak Power Speed | 2200 rpm
| Rated Speed | 2200 rpm
| Forward - 1 | 3.6 mph
| Forward - 2 | 6.3 mph
| Forward - 3 | 11 mph
| Forward - 4 | 19 mph
| Reverse - 1 | 4.1 mph
| Reverse - 2 | 7.2 mph
| Reverse - 3 | 12.5 mph
| Reverse - 4 | 21.5 mph
|
---|
|
Technical Specs |
Ground To Top Of Beacon | 13.1 ft in
| Ground To Top Of Hood | 8.6 ft in
| Height - Top Of Cab | 12.1 ft in
| Oscillation Angle | 10 degrees
| Ac Oil | 0.1 gal
| Oil Renewal System (Ors) | N/A
| Lift/Tilt System - Circuit | Pilot operated LS valve with EH
| Pilot System | Open center, fixed displacement gear
| Lift/Tilt System | Variable displacement piston
| Bore | 4.1 in
| Stroke | 5.3 in
| Operator Sound Level (Iso 6396) | 70 dB(A)
| Machine Sound Level (Iso 6395) | 110 dB(A)
| Note (1) | The operator sound pressure level was measured according to the test procedures and conditions specified in ISO 6396:2008. The measurement was conducted at the maximum engine cooling fan speed.
| Note (2) | Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
| Note (3) | The machine sound power level was measured according to the test procedures and conditions specified in ISO 6395:2008. The measurement was conducted at the maximum engine cooling fan speed.
|
---|
|